Calculators / Rectifier & Smoothing Capacitor Calculator

Rectifier & Smoothing Capacitor Calculator

Estimate half-wave or bridge rectifier ripple and DC output, or select an E12 smoothing capacitor.

Inputs

Try the prefilled example, or enter your own values.

Result

Calculate to see the result and worked steps. Changing an input clears the previous result.

How to use

  1. Choose half-wave or four-diode bridge and enter the isolated secondary RMS voltage.
  2. Enter AC frequency, fixed diode drop and constant DC load current.
  3. Analyze capacitance or select an E12 value at least as large as the calculated requirement.

Formula and assumptions

Vpeak ≈ √2Vrms − nVf. fripple = fAC (half-wave), or 2fAC (bridge). ΔVpp ≈ Iload/(frippleC). VDC ≈ Vpeak − ΔVpp/2.

Isolated low-voltage sinusoidal secondary, constant-current load, fixed diode drops, instantaneous recharge and linear discharge. Limited to ≤20% peak ripple. The plot is the approximate discharge envelope, not simulated diode conduction. Transformer regulation, surge and capacitor ESR/ripple-current ratings are omitted.

Sources

Worked example

A 12 Vrms, 50 Hz secondary and bridge with 0.7 V per diode gives a 15.571 V charged peak. At 100 mA with 1000 µF, ripple is about 1 Vpp and average output 15.071 V.

Common mistakes

RMS AC voltage is not the charged peak. A bridge has two conducting diode drops and twice the AC ripple frequency. This is a low-voltage circuit estimate, not a mains wiring design.