- Choose ideal ADC plus divider, or the NTC Beta model.
- For ADC, enter reference and sensor voltage; Rtop=0 provides a direct connection.
- For NTC, enter R0, its reference temperature and the appropriate Beta value, then solve resistance or temperature.
Formula and assumptions
ADC: LSB = Vref/2ᴺ; code = min(2ᴺ−1, floor(Vpin/LSB)). NTC: R(T) = R0 exp[B(1/T − 1/T0)], temperatures in kelvin.
ADC uses an explicitly defined unipolar floor-coded transfer with bins [kLSB, (k+1)LSB), clipped at full scale. It ignores offset, noise, gain error and sample/hold loading. NTC uses a constant Beta approximation with no self-heating or tolerance model; −100 to 300 °C is a calculator range, not a part rating.
Sources
Worked example
An ideal 12-bit, 3.3 V ADC has 805.664 µV per LSB. A 5 V sensor through equal 10 kΩ divider resistors gives 2.5 V and floor-coded output 3103. A 10 kΩ NTC at its 25 °C reference remains 10 kΩ.
Common mistakes
LSB uses 2ᴺ, not 2ᴺ−1. An endpoint line-fit and a particular ADC’s transition convention can differ from this floor model. Use NTC temperature tables or Steinhart–Hart when the Beta approximation is insufficient.